Electrocardiograph - Patient Input Circuit : Fully Floating And Isolated - Defibrillation Protected - YASHAM Brand - Company "Dahian Pezeshki Pishro" - Code 310 Buy Wholesale Price | Zoodel Wholesale Marketplace
Electrocardiograph - Patient Input Circuit : Fully Floating And Isolated - Defibrillation Protected - YASHAM Brand - Company "Dahian Pezeshki Pishro" - Code 310
Reporting incorrect contentReporting incorrect content

Product Details

  • Iran
  • Patient input circuit: fully floating and isolated, defibrillation protected, Class I, Type CF
  • 12-channel or rhythm display
  • 12 simultaneous leads on display
  • 6.25/12.5/25/50 mm/s
  • 2.5/5/10/20 mm/mV
  • 1/2/3-channel recording from 12 leads, and 1/2 leads plus Rhythm
  • Date, time, filter, speed
  • 1, 1+1, 2, 2+1, 3-channel, rhythm mode
  • 25, 35, 75 or 150 Hz
  • Simultaneous recording from 12 leads
  • 1000 samples per second
  • 65H * 260L * 210W mm, approximate weight 1.8 kg
  • 110*65 mm , 800*480 dots resolution
  • Power source, battery status, date, time
  • 8 hours of normal use
  • 90-264V, 50/60Hz
  • Thermal paper, width 63 mm
  • Thermal printer, vertical resolution 8 dots/mm

Description

Environmental conditions: 

Temperature, operating: 10°C to 40°C

Temperature, storage: -10°C to 50°C

Relative humidity: 25% to 95% (no condensation)

Standards: 

Safety: IEC (EN) 60601-1, IEC (EN) 60601-1-2(EMC) 

Performance: IEC (EN) 60601-2-25 
Software: EN62304

Protection class: I according to IEC 60601-1(with internal power supply) 

Applied part: CF according to IEC 60601-1 

 

 

 

 

 

 

 

 
Optional Interface:
USB HOST (FS/HS Speed -5Vdc-MAX. 500 mA) 
USB DEVICE (FS/HS Speed -5Vdc-MAX. 500 mA)                                                                                                       
LAN (RJ-45) (10/100 M/B – UDP/TCP/IP)                                
WiFi
SD Card

 

USB Host: for upgrading firmware by qualified operator.

USB Device: for transferring data to PC or any host device.

LAN (RJ-45): This port is used in order to communicate with central server or hub for data transfer.

One can use this port for communicating with hospital PACS system.

PACS: Picture Archiving and Communication System

WiFi: is used in the place which wiring is not possible. This method is used for transferring data from device to sever of reference PC.

One can use this method for communicating with hospital PACS system.

SD Card: for saving recorded ECG signal data on SD card.